OUTPUTS

Name

Describe the output and enter its function (e.g., Siren, Gate Opening, Watering, Lighting, Valve Closing). This description will later be displayed on the keypad, in the event log, and in the mobile app, greatly simplifying system operation and maintenance.

Serial Number

After scanning the wireless device performing the output function, the device’s serial number will be displayed here.

Scanning

To add a PowerG wireless siren in the configuration program, press the Scan button for the output number to which you want to add the siren. At the same time, press and hold the Enroll button on the siren. The red LED will light up. When the green LED stays on steadily, release the button; the siren has been added, and its serial number will appear in the program. An additional menu (Advanced Settings) is available via the right mouse button, where you can set the siren volume, the duration of the visual alarm, the enclosure tamper response, and the LED indicating communication with the system.

Output Type

Temporary NO

Temporary (Pulse) - NO (monostable, normally open)

Temporary NC

Temporary (Pulse) - NC (monostable, normally closed)

Permanent NO Permanent - NO (bistable, normally open)

Permanent NC

Permanent - NC (bistable, normally closed)

Output Duration

Parameter specifying the PGM output duration. Applies only to time-based outputs. Range from 1 to 9999 seconds.

Partition Assignment

Select the partitions whose events will trigger output actions. For System- and Zone-related actions, you cannot select a partition.

Event Types Depending on Action Type

By System

• Bell: An output signaling alarms. It will be activated if alarms occur in the system.
• Fire Detector Power Supply: The output is active in the normal state (NC). It is used to power reset-type fire detectors. The output is reset after a fire alarm is cleared.
• Trouble: The output will be activated if any trouble occurs in the system.
• Time Loss: The output will be activated if a problem with the system clock occurs.
• Loss of ~230V Power: The output will be activated in the event of a loss of AC power.
• Battery Failure: The output will be activated if the battery voltage drops below 11V.
• Bus Failure: The output will be activated if the control panel loses communication with any module installed in the system.
• Siren failure: The output will be activated if the siren is not connected to the BELL output.
• GSM failure: The output will be activated if the GSM module cannot log into the network.
• No GSM coverage: The output will be activated if there is no GSM network coverage.
• No GPRS coverage: The output will be activated if there is no GPRS network coverage.
• GSM/GPRS jamming: The output will be activated in the event of a sudden drop in GSM/GPRS signal strength.
• Communication error: The output will be activated if a problem occurs with the connection to the SM receiver and the control panel does not receive a KISSOFF signal within the programmed time and number of attempts.
• Scheduled maintenance: The output will be activated when a routine maintenance visit is required.
• Trouble Group – Connectivity: The output will be activated if a connectivity-related trouble occurs in the system—GSM Trouble, GPRS Coverage Trouble, GSM Coverage Trouble, Jamming Trouble, Communication Trouble
• Trouble group – power supply: The output will be activated if a power-related trouble occurs in the system—AC trouble, battery trouble, AUX trouble.
• Tamper alarm: The output will be activated if a tamper alarm occurs in the partition assigned to the output.
• Keypad tamper alarm: The output will be activated if a keypad tamper alarm occurs in the partition assigned to the output (e.g., the keypad is detached from the wall).

By Partition

• User-Controlled Output An output that can be controlled by the user (via the keypad, mobile app, and CLIP notifications). Linked to the Users / CLIP tab. Only after selecting/enabling this output function will cells associated with the added output be added to the CLIP menu. Until then, in the CLIP tab, you can only enter a phone number, but you cannot assign any output response.
• User-Controlled Output – Schedule An output that can be controlled by the user (via the keypad or mobile app) or via a schedule. This type of output is not controlled via CLIP notifications.
• Intrusion Alarm The output will be activated if an intrusion alarm occurs in the partition assigned to the output.
• Panic alarm: The output will be activated if a panic alarm occurs in the partition assigned to the output.
• 24-hour zone alarm: The output will be activated if an alarm from any 24-hour zone occurs in the partition assigned to the output.
• Fire Alarm: The output will be activated if a fire alarm occurs in the partition assigned to the output.
• Verified Alarm: The output will be activated if a verified alarm occurs in the partition assigned to the output.
• Panic alarm from the keypad: The output will be activated if a panic alarm is generated from the keypad.
• Fire alarm from the keypad: The output will be activated if a fire alarm is generated from the keypad.
• Medical alarm from the keypad: The output will be activated if a medical alarm is generated from the keypad.
• Duress alarm: The output will be activated if a duress code is entered.
• System status – armed The output will be activated if the partitions assigned to it are armed—regardless of the arming mode (full/night)
• System status – armed in full arming mode The output will be activated if all partitions assigned to it are armed in full arming mode.
• System status – armed in night mode The output will be activated if all partitions assigned to it are armed in night mode.
• System status – disarmed The output will be activated if all partitions assigned to it are disarmed.
• Entry delay The output is active during the entry delay.
• Exit delay The output is active during the exit delay.

• Incorrect Code: The output will be activated after 3 attempts to enter an incorrect code. It will be cleared after entering the correct access code.

By Zone

• Zone Alarm: The output will be activated if an alarm occurs on the specified zone.
• Zone Monitoring: The output reflects the status of the monitoring zone.
• Zone Number: A parameter specifying the zone number when the Action Type is set to “By Zone.”